Elite level A floodlight illuminance

Eh ave

(average horizontal illuminance)

>2,000 lux

Uniformity U1h

>0.50

Uniformity U2h

>0.70

Ev ave-0°

(vertical illuminance on 0° reference plane)

average >1,500 lux

minimum >1,000 lux

Uniformity U1v-0°

>0.50 *(see Pitch illuminance system design)

Uniformity U2v-0°

>0.60 *(see Pitch illuminance system design)

Ev ave-90°

(vertical illuminance on 90° reference plane)

average >1,500 lux

minimum >1,000 lux

Uniformity U1v-90°

>0.50 *(seePitch illuminance system design)

Uniformity U2v-90°

>0.60 *(see Pitch illuminance system design)

Ev ave-180°

(vertical illuminance on 180° reference plane)

average >1,500 lux

minimum >1,000 lux

Uniformity U1v-180°

>0.50 *(see Pitch illuminance system design)

Uniformity U2v-180°

>0.60 *(seePitch illuminance system design)

Ev ave-270°

(vertical illuminance on 270° reference plane)

average >1,500 lux

minimum >1,000 lux

Uniformity U1v-270°

>0.50 *(see Pitch illuminance system design)

Uniformity U2v-270°

>0.60 *(seePitch illuminance system design)

Match continuity mode (MCM)

* This applies to LED.

No disruption permitted for HID

See FPSL A

Flicker factor (FF)

average <3%

maximum <3%

Minimum adjacent uniformity ratio (MAUR)

>0.60

≤10 failures

Colour temperature (Tc)

5,000–6,200K

Colour rendering (Ra)

≥80 Ra

Glare rating (RG)

<50

Maintenance factor (MF)

0.90 LED